Fvf 338

 

Fvf 338

Content of PetroWiki is intended for personal use only and to supplement, not replace, engineering judgment. SPE disclaims any and all liability for your use of such content. More information

Rod P. Batycky ,Marco R. Thiele, StreamSim Technologies, Inc.; K.H. Coats, Coats Engineering, Inc.; Alan Grindheim, Dave Ponting, Roxar Software Solutions; John E. Killough, Landmark Graphics; Tony Settari, U. of Calgary and Taurus Reservoir Solutions Ltd.; L. Kent Thomas, ConocoPhillips; John Wallis, Wallis Consulting Inc.; J.W. Watts, Consultant; and Curtis H. Whitson, Norwegian U. of Science and Technology and Pera

Implementation is an important factor in the relative efficiencies of different formulations. For a given problem, different models using the same formulation can give widely different CPU times. For example, the IMPES CPU times reported by different participants in the six-component compositional SPE5 problem [6] differed by a factor of over 50.